SetOverwrite {Steel AISC 360 05/IBC 2006}

SetOverwrite

Syntax

SapObject.SapModel.DesignSteel.AISC360_05_IBC2006.SetOverwrite

VB6 Procedure

Function SetOverwrite(ByVal Name As String, ByVal Item As Long, ByVal Value As Double, Optional ByVal ItemType As eItemType = Object) As Long

Parameters

Name

The name of an existing frame object or group, depending on the value of the ItemType item.

Item

This is an integer between 1 and 43, inclusive, indicating the overwrite item considered.

1 = Framing type

2 = Omega0

3 = Consider deflection

4 = Deflection check type

5 = DL deflection limit, L/Value

6 = SDL + LL deflection limit, L/Value

7 = LL deflection limit, L/Value

8 = Total load deflection limit, L/Value

9 = Total camber limit, L/Value

10 = DL deflection limit, absolute

11 = SDL + LL deflection limit, absolute

12 = LL deflection limit, absolute

13 = Total load deflection limit, absolute

14 = Total camber limit, absolute

15 = Specified camber

16 = Net area to total area ratio

17 = Live load reduction factor

18 = Unbraced length ratio, Major

19 = Unbraced length ratio, Minor

20 = Unbraced length ratio, Lateral Torsional Buckling

21 = Effective length factor, K1 Major

22 = Effective length factor, K1 Minor

23 = Effective length factor, K2 Major

24 = Effective length factor, K2 Minor

25 = Effective length factor, K Lateral Torsional Buckling

26 = Moment coefficient, Cm Major

27 = Moment coefficient, Cm Minor

28 = Bending coefficient, Cb

29 = Nonsway moment factor, B1 Major

30 = Nonsway moment factor, B1 Minor

31 = Sway moment factor, B2 Major

32 = Sway moment factor, B2 Minor

33 = Reduce HSS thickness

34 = HSS welding type

35 = Yield stress, Fy

36 = Expected to specified Fy ratio, Ry

37 = Compressive capacity, Pnc

38 = Tensile capacity, Pnt

39 = Major bending capacity, Mn3

40 = Minor bending capacity, Mn2

41 = Major shear capacity, Vn2

42 = Minor shear capacity, Vn3

43 = Demand/capacity ratio limit

Value

The value of the considered overwrite item.

1 = Framing type

0 = Program Default

1 = SMF

2 = IMF

3 = OMF

4 = SCBF

5 = OCBF

6 = OCBFI

7 = EBF

2 = Omega0

Value >= 0; 0 means use a program determined value.

3 = Consider deflection

0 = Program default

1 = No

2 = Yes

4 = Deflection check type

0 = Program default

1 = Ratio

2 = Absolute

3 = Both

5 = DL deflection limit, L/Value

Value >= 0; 0 means no check for this item.

6 = SDL + LL deflection limit, L/Value

Value >= 0; 0 means no check for this item.

7 = LL deflection limit, L/Value

Value >= 0; 0 means no check for this item.

8 = Total load deflection limit, L/Value

Value >= 0; 0 means no check for this item.

9 = Total camber limit, L/Value

Value >= 0; 0 means no check for this item.

10 = DL deflection limit, absolute

Value >= 0; 0 means no check for this item. [L]

11 = SDL + LL deflection limit, absolute

Value >= 0; 0 means no check for this item. [L]

12 = LL deflection limit, absolute

Value >= 0; 0 means no check for this item. [L]

13 = Total load deflection limit, absolute

Value >= 0; 0 means no check for this item. [L]}

14 = Total camber limit, absolute

Value >= 0; 0 means no check for this item. [L]

15 = Specified camber

Value >= 0. [L}

16 = Net area to total area ratio

Value >= 0; 0 means use program default value.

17 = Live load reduction factor

Value >= 0; 0 means use program determined value.

18 = Unbraced length ratio, Major

Value >= 0; 0 means use program determined value.

19 = Unbraced length ratio, Minor

Value >= 0; 0 means use program determined value.

20 = Unbraced length ratio, Lateral Torsional Buckling

Value >= 0; 0 means use program determined value.

21 = Effective length factor, K1 Major

Value >= 0; 0 means use program determined value.

22 = Effective length factor, K1 Minor

Value >= 0; 0 means use program determined value.

23 = Effective length factor, K2 Major

Value >= 0; 0 means use program determined value.

24 = Effective length factor, K2 Minor

Value >= 0; 0 means use program determined value.

25 = Effective length factor, K Lateral Torsional Buckling

Value >= 0; 0 means use program determined value.

26 = Moment coefficient, Cm Major

Value >= 0; 0 means use program determined value.

27 = Moment coefficient, Cm Minor

Value >= 0; 0 means use program determined value.

28 = Bending coefficient, Cb

Value >= 0; 0 means use program determined value.

29 = Nonsway moment factor, B1 Major

Value >= 0; 0 means use program determined value.

30 = Nonsway moment factor, B1 Minor

Value >= 0; 0 means use program determined value.

31 = Sway moment factor, B2 Major

Value >= 0; 0 means use program determined value.

32 = Sway moment factor, B2 Minor

Value >= 0; 0 means use program determined value.

33 = Reduce HSS thickness

0 = Program default

1 = No

2 = Yes

34 = HSS welding type

0 = Program default

1 = ERW

2 = SAW

35 = Yield stress, Fy

Value >= 0; 0 means use program determined value. [F/L
2
]

36 = Expected to specified Fy ratio, Ry

Value >= 0; 0 means use program determined value.

37 = Compressive capacity, Pnc

Value >= 0; 0 means use program determined value. [F]

38 = Tensile capacity, Pnt

Value >= 0; 0 means use program determined value. [F]

39 = Major bending capacity, Mn3

Value >= 0; 0 means use program determined value. [FL]

40 = Minor bending capacity, Mn2

Value >= 0; 0 means use program determined value. [FL]

41 = Major shear capacity, Vn2

Value >= 0; 0 means use program determined value. [F]

42 = Minor shear capacity, Vn3

Value >= 0; 0 means use program determined value. [F]

43 = Demand/capacity ratio limit

Value >= 0; 0 means use program determined value.

ItemType

This is one of the following items in the eItemType enumeration:

Object = 0

Group = 1

SelectedObjects = 2

If this item is Object, the assignment is made to the frame object specified by the Name item.

If this item is Group, the assignment is made to all frame objects in the group specified by the Name item.

If this item is SelectedObjects, assignment is made to all selected frame objects and the Name item is ignored.

Remarks

This function sets the value of a steel design overwrite item.

The function returns zero if the item is successfully set; otherwise it returns a nonzero value.

VBA Example

Sub SetSteelDesignOverwriteItemAISC360_05_IBC2006()

'dimension variables

Dim SapObject as cOAPI

Dim SapModel As cSapModel

Dim ret As Long

'create Sap2000 object

Set SapObject = CreateObject("CSI.SAP2000.API.SapObject")

'start Sap2000 application

SapObject.ApplicationStart

'create SapModel object

Set SapModel = SapObject.SapModel

'initialize model

ret = SapModel.InitializeNewModel

'create model from template

ret = SapModel.File.New2DFrame(PortalFrame, 2, 144, 2, 288)

'set steel design code

ret = SapModel.DesignSteel.SetCode("AISC360-05/IBC2006")

'set overwrite item

ret = SapModel.DesignSteel.AISC360_05_IBC2006.SetOverwrite("8", 1, 7)

'close Sap2000

SapObject.ApplicationExit False

Set SapModel = Nothing

Set SapObject = Nothing

End Sub

Release Notes

Initial release in version 11.03.

See Also

GetOverwrite